• Hydrostatic Test Isolation Valves,Honyen,Hydrostatic Test Isolation Valves | Reheat Systems | Honyen
  • Hydrostatic Test Isolation Valves,Honyen,Hydrostatic Test Isolation Valves | Reheat Systems | Honyen
  • Hydrostatic Test Isolation Valves,Honyen,Hydrostatic Test Isolation Valves | Reheat Systems | Honyen
  • Hydrostatic Test Isolation Valves,Honyen,Hydrostatic Test Isolation Valves | Reheat Systems | Honyen

Hydrostatic Test Isolation Valves

HEVC hydrostatic test isolation valves establish temporary test boundaries in boiler steam systems. The SD61H arrangement uses a removable isolation plate during hydrostatic testing; after testing, the plate is replaced by a flow guide for normal operation. Cast and forged configurations support different steam-line materials, including cold-reheat and high-temperature hot-reheat installations.
Technical Specifications Product Scope
Product family Hydrostatic test isolation valves
Selected series SD61H
Size Range DN225-DN1000; configuration-specific
Pressure Rating Class300-3000SPL; special project ratings available
Body materials WCB, WC6, WC9, C12A, A105, F22, F91, F92 and other specified grades
Typical installation Superheater outlet; reheater inlet / outlet
Design references ASME B16.34; JB/T3595, as applicable
Download
View all downloads
  • Hydrostatic Test Isolation Valves,Honyen,Hydrostatic Test Isolation Valves | Reheat Systems | Honyen
  • Hydrostatic Test Isolation Valves,Honyen,Hydrostatic Test Isolation Valves | Reheat Systems | Honyen

Description

Design & Construction

  • Removable test isolation plate

    The isolation plate separates the required system sections during the overall hydrostatic test.

  • Flow guide for normal operation

    After testing, the test plate is replaced with a flow-guiding arrangement for normal operation.

  • Cast and forged configurations

    Available body constructions accommodate different steam-line material and operating requirements.

  • Cold- and hot-reheat examples

    SD61H-400SPL examples include DN800 / WCC cold-reheat arrangements; SD61H-960SPL examples include DN800 / F92 hot-reheat arrangements.

Typical Duty / Applications

  • Superheater Outlet

    Temporary isolation for boiler hydrostatic testing.

  • Cold Reheat

    Reheater-inlet and cold-leg isolation at the test boundary.

  • Hot Reheat

    Test isolation in high-temperature reheat piping.

Project References

Project Reference – Generating Units Selected Specification / Material Design Pressure (MPa) Design Temperature (°C)
2 x 1052MW ultra-supercritical DN800; WCC 6.7 355
2 x 1050MW ultra-supercritical DN750; SA-105 7.4 374
2 x 1100MW ultra-supercritical DN750; SA-105 7.25 390

Testing & Documentation

  • Test arrangement

    Isolation-plate installation, the hydrostatic test boundary and flow-guide conversion define the test arrangement.

  • Inspection and testing

    Pressure and leakage testing form part of the specified inspection scope.

  • Technical documentation

    Available project documentation can include valve drawings, model-specific datasheets, material records, inspection and test plans, test reports and operating instructions.

Related Power Generation Valves

Explore the complete Power Generation Valve portfolio →

Let's Discuss Your Project

Send us your RFQ, datasheets, BOMs, drawings or specifications for review and quotation.
Full Name*
Email*
Company Name
Project / Product Requirements
File Upload
Upload RFQ, datasheets, drawings, BOMs or specifications.